| PWR-75-48 (MEAN WELL -- XDR-75E-48) |
| Hardware Version |
2 |
| Dimensions (W x H x D) |
30 x 125 x 116 mm |
| Weight |
400g |
| Input Voltage |
85 ~ 264VAC, 50/60Hz
127 ~ 370VDC
[DC input operation possible by connecting AC/L(+), AC/N(-)] |
| Power Output |
75 watts,48V, 1.6A |
| Temperature |
Operating:-40~70 degrees C (**)
Storage:-40~85 degrees C |
| Humidity |
Operating: 20 ~ 95% (non-condensing)
Storage: 10 ~ 95% (non-condensing) |
| Installation |
DIN rail TS-35/7.5 or 15 |
| Safety & Function |
UL61010; BS EN/EN62368-1, BS EN/EN61558-1/-2-16, / ; CB IEC62368-1, IEC61558-1, ; TUV BS EN EN61010 IEC61010
RCM AS/NZS 61558-1/-2-16; BSMI CNS1 -1; CCC GB4943.1
EAC TPTC004 approved; KC KC62368-1 BIS IS13252 (Part 1):2010 certified |
| Remark |
*The specification is for PWR-75-48 hardware version 2 only.
** Please refer to output load derating curve from product specification. |
| PWR-120-48 (MEAN WELL -- XDR-120E-48) |
| Hardware Version |
3 |
| Dimensions (W x H x D) |
30 x 125 x 116 mm |
| Weight |
420g |
| Input Voltage |
85 ~ 264VAC, 50/60Hz
127 ~ 370VDC
[DC input operation possible by connecting AC/L(+), AC/N(-)] |
| Power Output |
120 watts, 48V, 2.5A |
| Temperature |
Operating:-40~70 degrees C (**)
Storage:-40~85 degrees C |
| Humidity |
Operating: 20 ~ 95% (non-condensing)
Storage: 10 ~ 95% (non-condensing) |
| Installation |
DIN rail TS-35/7.5 or 15 |
| Safety & Function |
UL61010; BS EN/EN62368-1, BS EN/EN61558-1/-2-16, / ; CB IEC62368-1, IEC61558-1, ; TUV BS EN EN61010 IEC61010
RCM AS/NZS 61558-1/-2-16; BSMI CNS1 -1; CCC GB4943.1
EAC TPTC004 approved; KC KC62368-1 BIS IS13252 (Part 1):2010 certified |
| Remark |
*The specification is for PWR-120-48 hardware version 3 only.
** Please refer to output load derating curve from product specification. |
| PWR-240-48 (MEAN WELL -- XDR-240E-48) |
| Hardware Version |
3 |
| Dimensions (W x H x D) |
40 x 125 x 116 mm |
| Weight |
610g |
| Input Voltage |
85 ~ 264VAC, 50/60Hz
127 ~ 370VDC |
| Power Output |
240 watts, 48V, 5A |
| Temperature |
Operating: -40~70 degrees C (**)
Storage:-40~85 degrees C |
| Humidity |
Operating: 20 ~ 95% (non-condensing)
Storage: 10 ~ 95% (non-condensing) |
| Installation |
DIN rail TS-35/7.5 or 15 |
| Safety & Function |
UL61010; BS EN/EN62368-1, BS EN/EN61558-1/-2-16, / ; CB IEC62368-1, IEC61558-1, ; TUV BS EN EN61010 IEC61010
RCM AS/NZS 61558-1/-2-16; BSMI CNS1 -1; CCC GB4943.1
EAC TPTC004 approved; KC KC62368-1 BIS IS13252 (Part 1):2010 certified |
| Remrk |
*The specification is for PWR-240-48 hardware version 3 only.
** Please refer to output load derating curve from product specification. |
| PWR-480-48 (MEAN WELL -- XDR-480E-48) |
| Hardware Version |
3 |
| Dimensions (W x H x D) |
48 x 125 x 125mm |
| Weight |
890g |
| Input Voltage |
85 ~ 264VAC, 50/60Hz
127 ~ 370VDC |
| Power Output |
480 watts, 48V, 10A |
| Temperature |
Operating:-40~70 degrees C (**)
Storage:-40~85 degrees C |
| Humidity |
Operating:20~95%(non-condensing)
Storage: 10 ~ 95% (non-condensing) |
| Installation |
DIN rail TS-35/7.5 or 15 |
| Safety & Function |
UL61010; BS EN/EN62368-1, BS EN/EN61558-1/-2-16, / ; CB IEC62368-1, IEC61558-1, ; TUV BS EN EN61010 IEC61010
RCM AS/NZS 61558-1/-2-16; BSMI CNS1 -1; CCC GB4943.1
EAC TPTC004 approved; KC KC62368-1 BIS IS13252 (Part 1):2010 certified |
| Remark |
*The specification is for PWR-480-48 hardware version 3 only.
** Please refer to output load derating curve from product specification. |
| PWR-960-48 (MEAN WELL -- XDR-960E-48) |
| Hardware Version |
2 |
| Dimensions (W x H x D) |
96 x 125 x 132mm |
| Weight |
2.47kg |
| Input Voltage |
180 ~ 264VAC, 50/60Hz
254 ~ 370VDC |
| Power Output |
960 watts, 48V,20A |
| Temperature |
Operating:-40~70 degrees C (**)
Storage:-40~85 degrees C |
| Humidity |
Operating:20~95%(non-condensing)
Storage: 10 ~ 95% (non-condensing) |
| Installation |
DIN rail TS-35/7.5 or 15 |
| Safety & Function |
UL61010; BS EN/EN62368-1, BS EN/EN61558-1/-2-16, / ; CB IEC62368-1, IEC61558-1, ; TUV BS EN EN61010 IEC61010
RCM AS/NZS 61558-1/-2-16; BSMI CNS1 -1; CCC GB4943.1
EAC TPTC004 approved; KC KC62368-1 BIS IS13252 (Part 1):2010 certified |
| Remark |
*The specification is for PWR-960-48 hardware version 2 only.
** Please refer to output load derating curve from product specification. |